0
PGA309-HT
  • PGA309-HT

PGA309-HT

ACTIVE

Voltage Output Programmable Sensor Conditioner, PGA309-HT

Texas Instruments PGA309-HT Product Info

1 April 2026 5

Parameters

PGA/VGA

PGA

Number of channels

2

Vs (min) (V)

2.7

Vs (max) (V)

5.5

Input type

Differential

Output type

Single-ended

Input offset drift (±) (typ) (µV/°C)

0.2

Interface type

1-wire, Analog 2 Wire, UART

Noise at 1 kHz (typ) (V√Hz)

0.00000021

BW at Acl (MHz)

2

Acl, min spec gain (V/V)

4

Gain (max) (dB)

42

Architecture

CMOS

Features

High Temperature, Temperature sensing

Vos (offset voltage at 25°C) (typ) (mV)

0.003

Input voltage noise (typ) (µV√Hz)

0.21

Slew rate (typ) (V/µs)

0.5

Iq per channel (typ) (mA)

1.2

Gain error (typ) (%)

0.2

Gain drift (max) (ppm/°C)

10

Rating

High Temp

Operating temperature range (°C)

-55 to 150

Package

TSSOP (PW)-16-32 mm² 5 x 6.4

Features

  • Complete Bridge Sensor Conditioner
  • Voltage Output: Ratiometric or Absolute
  • Digital Cal: No Potentiometers/Sensor Trims
  • Sensor Error Compensation
    • Span, Offset, and Temperature Drifts
  • Low Error, Time-Stable
  • Sensor Linearization Circuitry
  • Temperature Sense: Internal or External
  • Calibration Lookup Table Logic
    • Uses External EEPROM (SOT23-5)
  • Over/Under-Scale Limiting
  • Sensor Fault Detection
  • +2.7V TO +5.5V Operation
  • Small TSSOP-16 Package
  • Complete Bridge Sensor Conditioner
  • Voltage Output: Ratiometric or Absolute
  • Digital Cal: No Potentiometers/Sensor Trims
  • Sensor Error Compensation
    • Span, Offset, and Temperature Drifts
  • Low Error, Time-Stable
  • Sensor Linearization Circuitry
  • Temperature Sense: Internal or External
  • Calibration Lookup Table Logic
    • Uses External EEPROM (SOT23-5)
  • Over/Under-Scale Limiting
  • Sensor Fault Detection
  • +2.7V TO +5.5V Operation
  • Small TSSOP-16 Package

Description

The PGA309 is a programmable analog signal conditioner designed for bridge sensors. The analog signal path amplifies the sensor signal and provides digital calibration for zero, span, zero drift, span drift, and sensor linearization errors with applied stress (pressure, strain, etc.). The calibration is done via a One-Wire digital serial interface or through a Two-Wire industry-standard connection. The calibration parameters are stored in external nonvolatile memory (typically SOT23-5) to eliminate manual trimming and achieve long-term stability.

The all-analog signal path contains a 2x2 input multiplexer (mux), auto-zero programmable-gain instrumentation amplifier, linearization circuit, voltage reference, internal oscillator, control logic, and an output amplifier. Programmable level shifting compensates for sensor dc offsets.

The core of the PGA309 is the precision, low-drift, no 1/f noise Front-End PGA (Programmable Gain Amplifier). The overall gain of the Front-End PGA + Output Amplifier can be adjusted from 2.7V/V to 1152V/V. The polarity of the inputs can be switched through the input mux to accommodate sensors with unknown polarity output. The Fault Monitor circuit detects and signals sensor burnout, overload, and system fault conditions.

For reference application information, see the commercial device PGA309 User's Guide (SBOU024) available for download at www.ti.com.

Subscribe to Welllinkchips !
Your Name
* Email
Submit a request