0
TC7106A
  • TC7106A
  • TC7106A
  • TC7106A
  • TC7106A

TC7106A

In Production

The TC7106A 3½ digit LCD direct-display drive analog-to-digital converters allow existing TC7106 based systems to be upgraded. Each device has a precision reference with a 20ppm/°C max temperature coefficient. This represents a 4-7 times improvement over similar 3½ digit converters. Existing TC7106 based systems may be upgraded without changing external passive component values. The TC7106A low power drain and 9V battery operation make it suitable for portable applications. The TC7106A reduces linearity error to less than 1 count. Rollover error (the difference in readings for equal magnitude but opposite polarity input signals) is below ±1 count. High impedance differential inputs offer 1pA leakage current and a 1012 Ohm input impedance. The differential reference input allows ratiometric...

Microchip Technology TC7106A Product Info

16 April 2026 0

Parameters

Hold function

Yes

DMM

No

Resolution Digits

3.5

Resolution Counts

2000

Temp Range Min

-25

Temp Range Max

85

Features

  • 20ppm/°C Typical
  • Drives LCD Display Directly
  • Guaranteed Zero Reading with Zero Input
  • Low Noise for Stable Display
  • Auto-Zero Cycle Eliminates Need for Zero Adjustment
  • True Polarity Indication for Precision Null Applications
  • Convenient 9 V Battery Operation
  • High Impedance CMOS Differential Inputs: 1012 Ohm
  • Differential Reference Inputs Simplify Ratiometric Measurements
  • Low Power Operation: 10mW

Description

The TC7106A 3½ digit LCD direct-display drive analog-to-digital converters allow existing TC7106 based systems to be upgraded. Each device has a precision reference with a 20ppm/°C max temperature coefficient. This represents a 4-7 times improvement over similar 3½ digit converters. Existing TC7106 based systems may be upgraded without changing external passive component values. The TC7106A low power drain and 9V battery operation make it suitable for portable applications. The TC7106A reduces linearity error to less than 1 count. Rollover error (the difference in readings for equal magnitude but opposite polarity input signals) is below ±1 count. High impedance differential inputs offer 1pA leakage current and a 1012 Ohm input impedance. The differential reference input allows ratiometric measurements for ohms or bridge transducer measurements. The 15µVp-p noise performance guarantees a great reading. The auto-zero cycle guarantees a zero display reading with a zero-volts input.

Subscribe to Welllinkchips !
Your Name
* Email
Submit a request