0
In Production
Description |
Dual DC Power/Energy Monitor with Accumulator |
Vsense min FSR (mV) |
-100 |
Vsense max FSR (mV) |
50, 100 |
Vsense accuracy (% FSR, max) |
0.5 |
Vbus Range min (V) |
0 |
Vbus Range max (V) |
32 |
Vbus accuracy (% FSR, max) |
0.25 |
Sampling Interval min (msec) |
0.2 |
Remote Temperature Monitors |
0 |
# Ambient Temperature Monitors |
0 |
Temperature Accuracy Typical (°) |
0 |
Temperature Accuracy Max (°) |
0 |
Alert/Therm |
2 |
Accumulator? |
Yes |
Interface |
SMBus/I2C |
Address Select |
16 |
# Current Channel |
1 |
ADC Resolution (bit) |
16 |
The PAC1951 is a power monitor and energy monitor that reports on bus voltage and sense voltage 16-bits of resolution. Power is reported as a simultaneous product of two 16-bit independent bus and sense voltages. All registers are accessible through I2C / SMBus including an 8 sample average for reading stability. The device can detect over/undervoltage, over/undercurrent and overpower against user programmed limits for each channel and generate ALERT outputs.
There are two versions of the PAC1951: the PAC1951-1 devices are for high-side current sensing and the PAC1951-2 devices are for low-side current sensing.