ACTIVE

Precision High-Speed Logarithmic Amplifier with 2.5V Reference and Uncommitted Output Op Amps

Texas Instruments LOG114 Product Info

1 April 2026 13

Parameters

Scale factor (V/decade)

0.375

Input current range (min) (nA)

0.1

Input current range (max) (mA)

10

Offset voltage (input amplifiers) (max) (mV)

4

Vs (±) (min) (V)

4.8

Vs (±) (max) (V)

11

Iq (max) (mA)

15

Dynamic range (typ) (dB)

160

Reference type

Internal

Auxiliary op amps

2

Full-scale output voltage (min) (±V)

-4.4

Full-scale output voltage (max) (±V)

4.4

Conformity error (initial 5 decades) (max) (%)

0.2

Conformity error (initial 5 decades) (typ. over temp) (%/°C)

0.1

Operating temperature range (°C)

0 to 70

Specified voltage (±V)

5

Rating

Catalog

Package

VQFN (RGV)-16-16 mm² 4 x 4

Features

  • Advantages:
    • Tiny for high density systems
    • Precision on one supply
    • Fast over eight decades
    • Fully-tested function
  • Two scaling amplifiers
  • Wide input dynamic range: eight decades, 100pA to 10mA
  • 2.5V reference
  • Stable over temperature
  • Low quiescent current: 10mA
  • Dual or single supply: ±5V, 5V
  • Package: Small QFN-16 (4mm × 4mm)
  • Specified temperature range: −5°C to 75°C
  • Advantages:
    • Tiny for high density systems
    • Precision on one supply
    • Fast over eight decades
    • Fully-tested function
  • Two scaling amplifiers
  • Wide input dynamic range: eight decades, 100pA to 10mA
  • 2.5V reference
  • Stable over temperature
  • Low quiescent current: 10mA
  • Dual or single supply: ±5V, 5V
  • Package: Small QFN-16 (4mm × 4mm)
  • Specified temperature range: −5°C to 75°C

Description

The LOG114 is specifically designed for measuring low-level and wide dynamic range currents in communications, lasers, medical, and industrial systems. The device computes the logarithm or log-ratio of an input current or voltage relative to a reference current or voltage (logarithmic transimpedance amplifier).

High precision is verified over a wide dynamic range of input signals on either bipolar (±5V) or single (5V) supply. Special temperature drift compensation circuitry is included on-chip. In log-ratio applications, the signal current can be from a high impedance source such as a photodiode or resistor in series with a low impedance voltage source. The reference current is provided by a resistor in series with a precision internal voltage reference, photo diode, or active current source.

The output signal at VLOGOUT has a scale factor of 0.375V/decade of input current, which limits the output so that the output fits within a 5V or 10V range. The output can be scaled and offset with one of the available additional amplifiers, so the output matches a wide variety of ADC input ranges. Stable DC performance allows accurate measurement of low-level signals over a wide temperature range. The LOG114 is specified over a −5°C to 75°C temperature range and can operate from −40°C to 85°C.