0
The BMI423 is a 6-axis inertial measurement unit that Bosch Sensortec positions at the intersection of two trends: the growing demand for always-on sensing in battery-constrained devices, and the desire to capture ever more dynamic motion without sacrificing precision. Announced at CES 2026, the BMI423 extends the measurement range to ±32 g on the accelerometer and ±4000 degrees per second on the gyroscope—double that of its predecessor—while maintaining a typical current consumption of just 25 µA for acceleration-based always-on tasks. Its most distinctive feature, however, is not inertial at all: the BMI423 integrates bone-conduction voice activity detection, allowing it to detect when a user is speaking without activating a microphone.
The table below consolidates the key specifications of the BMI423 from Bosch’s published documentation.
|
Parameter |
BMI423 Specification |
|
Accelerometer ranges |
±8 g, ±32 g (24-bit resolution) |
|
Gyroscope range |
±4000 °/s (24-bit resolution) |
|
Accelerometer noise density |
90 µg/√Hz (≤ 8 g); 120 µg/√Hz (≥ 16 g) |
|
Gyroscope noise density |
5.5 mdps/√Hz |
|
Typical current (accelerometer only, always-on) |
25 µA |
|
Typical current (full operation) |
575 µA |
|
Supply voltage (VDD) |
1.71 V to 3.63 V |
|
Supply voltage (VDDIO) |
1.08 V to 3.63 V |
|
Interface |
SPI (10 MHz), I3C (12.5 MHz), I2C (1 MHz Fm+) |
|
FIFO |
Up to 4 KB |
|
Package |
2.5 × 3.0 × 0.83 mm³ LGA-14 |
|
Operating temperature |
-40°C to +85°C |
Specifications drawn from Bosch product brief and datasheet.
The decision to double the measurement range relative to earlier generations reflects the reality of modern wearable use cases. A golf swing, a tennis serve, or a rapid robotic arm movement can generate acceleration peaks that saturate a ±16 g sensor. When saturation occurs, the motion data is clipped and the subsequent analysis—whether it is swing tempo, impact detection, or robot joint trajectory—becomes unreliable. The BMI423’s ±32 g range captures these high-dynamic events without clipping, while the 24-bit resolution ensures that smaller motions within the same signal path are still resolved with adequate precision.
The gyroscope’s ±4000 °/s range serves a similar purpose. Fast rotational movements, such as a wrist flick in a gesture-controlled interface or the rapid articulation of a robotic end effector, can exceed the range of conventional gyroscopes. The BMI423 maintains measurement integrity in these conditions, which matters for applications that need to recognize gestures or monitor machine motion without gaps in the data.
The VAD feature in the BMI423 is notable because it leverages the accelerometer to detect speech through bone conduction rather than through air pressure waves captured by a microphone. When a person speaks, vibrations propagate through the skull and jaw, producing subtle acceleration signals that the BMI423 can detect. The sensor then signals the system to wake the microphone only when speech is present.
This approach offers two benefits. First, it saves power: the microphone and its associated audio processing chain can remain off during silence, which is the majority of the time in most wearable scenarios. Second, it enhances privacy: the microphone is not continuously capturing audio, reducing the attack surface for unauthorized listening. For earbuds and hearables where battery capacity is measured in tens of milliampere-hours, the 25 µA always-on acceleration current combined with microphone gating can extend usage time between charges.
The BMI423 includes a suite of always-on features that run in the sensor’s ultra-low-power domain without waking the host processor. These include wrist gesture recognition, single/double/triple tap detection, step counting, and motion detection. For a smartwatch or fitness band, these functions allow the main MCU to remain in its deepest sleep state until a meaningful event occurs, at which point the BMI423 asserts an interrupt and the system wakes to process the event.
The on-chip FIFO buffer of up to 4 KB is large enough to store accelerometer, gyroscope, temperature, and timestamp data while the host is sleeping, further reducing wake frequency. Hardware synchronization between accelerometer, gyroscope, and temperature channels is maintained to within 1 µs, ensuring that fused data is temporally coherent.
The BMI423 is the appropriate choice when an application requires one or more of the following: high-dynamic-range motion capture, always-on operation with minimal power budget, or on-sensor voice activity detection for microphone gating. Wearables, hearables, and robotics are the three application categories Bosch explicitly targets.
For a smartwatch that tracks sports activities, the ±32 g range ensures that running, jumping, and racket sports are captured without saturation, while the always-on step counter and gesture recognition keep the main processor asleep during idle periods. For earbuds, the bone-conduction VAD provides a power-efficient way to trigger voice assistants or call handling without continuously running a microphone. For robotics, the extended range accommodates fast joint movements and the low noise supports precise position feedback.
The BMI423 is less suitable for applications that do not benefit from its wide dynamic range or VAD capability. A basic step counter or a low-cost gaming controller would not utilize the ±32 g range or the bone-conduction sensing, and a simpler IMU would be more cost-effective. Designers should also verify the operating temperature range: the BMI423 is specified from -40°C to +85°C, which covers consumer wearables but may be insufficient for industrial or automotive-adjacent applications.
The BMI423’s interface options—SPI at up to 10 MHz, I3C at 12.5 MHz, and I2C at 1 MHz—give developers flexibility in how they connect the sensor to their host MCU. I3C is particularly advantageous for wearables because it reduces pin count and supports in-band interrupts, but it requires a host controller that supports the protocol. I2C remains the most universally compatible option, though at lower throughput.
The bone-conduction VAD feature requires careful mechanical integration. The sensor must be acoustically coupled to the user’s head or ear canal in a way that allows bone-conducted vibrations to reach the accelerometer. In earbuds, this means the sensor should be mounted on a rigid portion of the housing that contacts the ear. The VAD algorithm’s sensitivity and threshold parameters are configurable, but tuning them for a specific mechanical design typically requires empirical testing with the target user population.